High-Flow, High-Pressure Process Pump | Megaroyal Series
Designed for your most critical industrial processing needs, the Megaroyal process pump delivers reliable, leak-free performance with a minimal footprint. The Megaroyal’s compact design makes it easy to integrate into O&G offshore platforms and FPSOs.
- •Material (fluid-contacting): 316L stainless steel / PVC
- •Maximum pressure: 3,854 psi / 252 bar (metallic fluid end)
- •Maximum flow rate: 12,680 gph / 48,000 lph (metallic liquid end)
- •Flow Variation Control: Manual / Remote
- •Certifications: API 675, EC, ATEX, IECEX
Why choose this product? (Why this product?)
High reliability in critical applications
Provides high reliability in critical chemical delivery applications to ensure optimal performance. (High reliability in critical chemical delivery applications for optimum performance.)
Space-saving thanks to its compact design
Compact design with a 25% smaller footprint, making it the right choice when space is limited. (Compact design with a 25% smaller footprint, making it the right fit when space is limited.)
Long service life and low maintenance
A patented diaphragm design with an estimated service life of over 20,000 hours reduces maintenance costs and protects against leaks. (Patented diaphragm design with a service life of over 20,000 hours reduces maintenance costs while protecting against leaks.)
Advanced lubrication for extended service life
A unique lubrication system reduces wear, minimizes maintenance, and extends the equipment's service life. (Unique lubrication system reduces wear, minimizes maintenance, and extends equipment life.)
Leak Detection (Double Diaphragm)
Equipped with a double-diaphragm detection system to monitor via local or remote alarm in the unlikely event of a rupture.
API 675 Compliance
Designed to fully comply with the strict API 675 standards to ensure consistent and accurate dosing.
Overview
The Megaroyal process pump is designed to provide absolute reliability in critical chemical delivery applications. It delivers high flow and high pressure, ensuring optimal performance even in the most demanding environments.
The compact design has a 25% smaller footprint compared to standard industrial pumps, making it the perfect solution for installations where space is limited, such as on offshore platforms and FPSOs. In addition to space savings, the pump features an advanced, unique lubrication system that significantly reduces wear, minimizes maintenance requirements, and extends the equipment’s overall service life.
Safety and continuous operation are ensured through a patented membrane design with a service life of over 20,000 hours. Megaroyal is also equipped with a state-of-the-art dual-diaphragm leak detection system, designed to monitor via local or remote alarms, and protects your process from leaks in the highly unlikely event of a rupture. It is fully API 675-compliant and guarantees consistent and accurate dosing.
Performance Data
TYPE HX 268 - 50 and 60 Hz Motors
| Plunger Diameter |
50 Hz Motor | 60 Hz Motor | Connections | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Stroke Speed Max. |
Motor Speed Max. |
Flow Rate Max. theoretical |
Max. Pressure |
Stroke Speed Max. |
Motor Speed Max. |
Flow Rate Max. theoretical |
Max. Pressure |
||
| spm | rpm | (L/h) | (bar) | spm | rpm | (gph) | (psi) | ||
| Ø | spm | rpm | (L/h) | (bar) | spm | rpm | (gph) | (psi) | |
| 55 | 146 | 1440 | 7492 | 252 | 140 | 1728 | 1979 | 3654 | Inlet 4"-HH3 Outlet 3"-HH3 |
| 60 | 146 | 1440 | 8916 | 212 | 140 | 1728 | 2355 | 3074 | Inlet 4"-HH3 Outlet 3"-HH3 |
| 63 | 146 | 1440 | 9830 | 192 | 140 | 1728 | 2596 | 2784 | Inlet 4"-HH3 Outlet 3"-HH3 |
| 65 | 146 | 1440 | 10464 | 181 | 140 | 1728 | 2764 | 2622 | Inlet 4"-HH3 Outlet 3"-HH3 |
| 70 | 146 | 1440 | 12136 | 155 | 140 | 1728 | 3206 | 2248 | Inlet 4"-HH3 Outlet 3"-HH3 |
| 75 | 146 | 1440 | 13932 | 135 | 140 | 1728 | 3680 | 1958 | Inlet 4"-HH3 Outlet 3"-HH3 |
TYPE HX 308 - 50 and 60 Hz Motors
| Plunger Diameter |
50 Hz Motor | 60 Hz Motor | Connections | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Stroke Speed Max. |
Motor Speed Max. |
Flow Rate Max. theoretical |
Max. Pressure |
Stroke Speed Max. |
Motor Speed Max. |
Flow Rate Max. theoretical |
Max. Pressure |
||
| spm | rpm | (L/h) | (bar) | spm | rpm | (gph) | (psi) | ||
| Ø | spm | rpm | (L/h) | (bar) | spm | rpm | (gph) | (psi) | |
| 80 | 146 | 1440 | - | 119 | 140 | 1728 | 2187 | 1225 | Inlet 5"-HH3 Outlet 4"-HH3 |
| 85 | - | 1440 | 17995 | 105 | 140 | 1728 | 4727 | 1522 | Inlet 5"-HH3 Outlet 4"-HH3 |
| 90 | 146 | 1440 | 20063 | 94 | 140 | 1728 | 5200 | - | Inlet 5"-HH3 Outlet 4"-HH3 |
| 95 | 146 | 1440 | 22353 | - | 140 | 1728 | 5105 | 1218 | Inlet 5"-HH3 Outlet 4"-HH3 |
| 100 | 146 | 1440 | 24708 | - | 140 | 1728 | 6543 | 1102 | Inlet 5"-HH3 Outlet 4.5"-HH3 |
| 105 | 146 | 1440 | 27307 | - | 140 | 1728 | 7213 | 1000 | Inlet 5"-HH3 Outlet 4.5"-HH3 |
TYPE HX 368 - 50 and 60 Hz Motors
| Plunger Diameter |
50 Hz Motor | 60 Hz Motor | Connections | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Stroke Speed Max. |
Motor Speed Max. |
Flow Rate Max. theoretical |
Max. Pressure |
Stroke Speed Max. |
Motor Speed Max. |
Flow Rate Max. theoretical |
Max. Pressure |
||
| spm | rpm | (L/h) | (bar) | spm | rpm | (gph) | (psi) | ||
| Ø | spm | rpm | (L/h) | (bar) | spm | rpm | (gph) | (psi) | |
| 110 | 146 | 1440 | 29969 | 63 | 140 | 1728 | 7917 | 912 | Inlet 6"-HH3 Outlet 5"-HH3 |
| 115 | 146 | 1440 | 32756 | - | 140 | 1728 | 1053 | - | Inlet 6"-HH3 Outlet 5"-HH3 |
| 120 | 146 | 1440 | 35666 | 53 | 140 | 1728 | 9422 | 268 | Inlet 6"-HH3 Outlet 5"-HH3 |
| 125 | 146 | 1440 | 38700 | 48 | 140 | 1728 | 10223 | 606 | Inlet 6"-HH3 Outlet 5"-HH3 |
| 130 | 146 | 1440 | 45058 | 45 | 140 | 1728 | 1053 | 602 | Inlet 6"-HH3 Outlet 5"-HH3 |
| 135 | 146 | 1440 | 45140 | 41 | 140 | 1728 | 11924 | 594 | Inlet 6"-HH3 Outlet 5"-HH3 |
| 140 | 146 | 1440 | 48545 | 38 | 140 | 1728 | 12824 | 565 | Inlet 6"-HH3 Outlet 5"-HH3 |
| 145 | 146 | 1440 | 52075 | 38 | 140 | 1728 | 13756 | 522 | Inlet 6"-HH3 Outlet 5"-HH3 |
Flow and Pressure Range
Dimensions
(in x in x in | mm x mm x mm)
-
HX268:
70.3 x 68.9 x 99.0
1750 x 1750 x 2500 -
HX308:
87.2 x 75.2 x 99.6
2215 x 1910 x 2530 -
HX368:
115.4 x 82.6 x 99.6
2930 x 2100 x 2530
Need help choosing?
We help you identify the right solution for your application, operating conditions, and performance requirements.
Scope of Use
For a wide range of processes:
The robust construction and API 675 compliance of Megaroyal pumps enable them to handle a wide variety of fluid types, including common chemicals, as well as viscous, abrasive, corrosive, and toxic fluids. They are widely used across several demanding industrial sectors:
- Oil and Gas: High-pressure fluid injection and transfer to prevent hydrate formation, reduce corrosion, and manage deposits.
- Chemical and Petrochemical: Precise dosing in refinery processes such as separation, distillation, and finishing.
- Water Treatment: Reliable dosing for municipal and industrial wastewater treatment.
- General Industry: Transfer of slurry, including bauxite, coal slurry, and heavy sewage.
Applications and Industries (Industries & Applications)
Megaroyal pumps can handle a wide variety of fluid types, including common chemicals, as well as viscous, slurry-containing, abrasive, corrosive, and shear-sensitive fluids. They are used across many different industrial sectors:
Oil and Gas
Applications that require high-pressure fluid injection to prevent hydrate formation and reduce corrosion and deposits.
Chemical Processing
Measurement of chemicals in refinery processes such as separation, distillation, and transformation.
Water Treatment
Reliable dosing for municipal and industrial water treatment.
General Industry
Pumping of high-viscosity slurries such as bauxite, coal slurry, and sewage. Ideal for industries that require zero leakage.
Frequently Asked Questions
What makes Megaroyal ideal for tight spaces?
Megaroyal features a compact design with a 25% smaller footprint compared to traditional high-pressure process pumps. This makes it an exceptional choice for integration on O&G offshore platforms, FPSOs, and any facility where floor space is limited, without sacrificing performance.
How does dual-diaphragm leak detection work?
The pump is equipped with a patented dual-diaphragm leak detection system. In the highly unlikely event of a rupture in the primary diaphragm, the system contains the fluid and immediately triggers either a local or remote alarm, ensuring zero leakage into the environment and allowing for safe shutdown and maintenance.
Is Megaroyal API 675 compatible?
Yes, the Megaroyal series is fully API 675-compliant, which ensures the consistent and accurate dosing required in demanding industrial applications.