Emission-free chemical injection | Vmac™ Series model D

The Vmac™ Series is an electrically driven positive displacement (plunger) pump, designed specifically to replace gas-driven pumps and prevent toxic emissions from escaping into the environment. It helps you meet strict regulatory requirements while improving operational efficiency. The Vmac™ model D uses dual spring-loaded lip seals and an integrated worm and gear drive that deliver unmatched reliability and environmental safety.

  • Ideal for: Oil and gas production, pipelines and process plants

  • Maximum pressure: Up to 344.7 bar (5,000 psi)

  • Maximum flow: Up to 171.7 l/d (45.4 gpd)

  • Key applications: Accurate injection of methanol, biocides, corrosion inhibitors, defoamers and H2S scavengers

Williams Vmac-serien modell D elektrisk plungerpumpe

Features

The Vmac™ Series model D is available in 2 different standard gear ratios and 3 plunger sizes to meet your exact process requirements. The pump is built with the following key features to ensure long service life and optimal operation:

  • Robust construction: Durable, powder-coated and sealed metal housing designed to withstand harsh environments.

  • Smooth flow: A solid metal worm and gear drive, combined with a variable eccentric stroke length mechanism, gives a 10:1 turndown ratio with a smoother flow.

  • Precision control: The accurate stroke length adjustment can be operated whether the pump is running or stopped.

  • Extended service life: All gear components move in a continuous oil bath. The proven Williams double sealing arrangement gives a longer, leak-free life, especially in combination with a ceramic plunger (standard version).

  • High accuracy: Steady-state accuracy of ± 1 % of full capacity across a 10:1 turndown range.

  • Material quality: Liquid end housing manufactured in 316 stainless steel (316SS) for excellent corrosion resistance.

  • Easy maintenance: No packing that requires re-adjustment. Suction and discharge check valves are supplied with composite seats for long life and 100 % positive sealing.

  • Optimal alignment: C-face direct motor mounting ensures perfect shaft alignment.

Documents

Performance

Vmac D Capacity / Pressure Table

Plunger Gear Ratio Strokes/
Min 60 Hz
1725 RPM
Capacity/ Pressure @ 60 HZ
Diameter Code Ratings at 100 psi Capacity at Max Pressue
GPD LPD GPD LPD PSI BAR
1/4"
6.35mm
250 40:1 43 5.4 20.4 3.7 13.9 5000 344.7
20:1 86 10.8 40.9 7.6 28.6 5000 344.7
3/8"
9.5mm
375 40:1 43 12.5 47.4 11.0 41.7 2250 155.1
20:1 86 23.8 89.9 20.7 78.5 2250 155.1
1/2"
12.7mm
500 40:1 43 22.5 85.0 21.2 80.1 1250 86.2
20:1 86 45.4 171.7 41.0 155.3 1250 86.2
Plunger Gear Ratio Strokes/
Min 50 Hz
1425 RPM
Capacity/ Pressure @ 50 HZ
Diameter Code Ratings at 100 psi Capacity at Max Pressue
GPD LPD GPD LPD PSI BAR
1/4"
6.35mm
250 40:1 36 4.5 17.0 3.1 11.6 5000 344.7
20:1 72 9.0 34.1 6.3 23.8 5000 344.7
3/8"
9.5mm
375 40:1 36 10.4 39.5 9.2 34.7 2250 155.1
20:1 72 19.8 74.9 17.3 65.4 2250 155.1
1/2"
12.7mm
500 40:1 36 18.7 70.8 17.6 66.7 1250 86.2
20:1 72 37.8 143 34.2 129.4 1250 86.2
Note: Motor requirements: 1/4 HP or 0.25 Kw